Duct
Detectors
The Duct detector samples air
currents passing through a duct and gives dependable performance for management fans,
blowers, and air-conditioning systems, preventing the spread of toxic smoke and fire gases
through the protected area. Duct detectors are not a substitute for an open-area smoke
detector, an early warning detection, or a building's regular fire detection system.
Beam
Detectors
Beam detectors are ideal to meet
the unique fire protection challenge of atriums and other open
areas with high ceilings. A beam detector is particularly well
suited for use in ballrooms, churches, warehouses, museums,
factories where conventional smoke detectors cannot be easily
installed. It has a receiver and transmitter that can be powered
separately. The projected "beam" detects a reduction
in the signal, working well with smoke and fast-flame fires.
Sensitivity is selectable between 30% or 55% Total Obscuration.
Detect-A-Fire
Heat Detection

Rate-compensated
for quicker response. Rugged outer shell, easy-to-install coupling
and wire leads. Self resetting and intrinsically safe with listed
barriers. Explosion-proof and hermetically sealed, designed
for corrosive and high temperature/humidity environments. Rated
140°F 725°F.
Detect-a-Fire Unit (Horizontal) Installation
Sheet
Detect-a-Fire Unit (Vertical) Installation Sheet
Chemtronics
Heat Detection
|
Built tough
to withstand the rigors of commercial & industrial applications.
Weather/moisture proof or explosion/moisture proof variants.
Compact, "open circuit" devices in either Rate-of-Rise
and/or Fixed Temperature configuration.
|
Heat Detectors Series 400 Fixed Temperature Data
Sheet
Heat Detectors Series 500 Fixed Temperature Data
Sheet
Heat Detectors Series 500 Special
Fixed Temperature Data Sheet
Heat Detectors Series 600 Fixed Temperature Data
Sheet
Rate
Compensated Detectors
The rate-anticipation detectors respond and activate the
fire alarm immediately whenever the ambient temperature reaches the preset temperature
setting. Under rapid heat rise conditions, the rate-anticipation feature enables the
detector to respond one to three degrees ahead of the setting. At the same time however,
it does not respond to momentary temperature fluctuations below the selected protection
level, thus eliminating false alarms. When temperature drops back down below the
protection level, the detector automatically resets itself.
Rate of Rise
Detectors
The rate-of-rise is ideal for areas in which a smoke
detector is not practical. Independent studies show that heat detectors should be used
when property protection alone is involved. The rate-of-rise detector activates when the
ambient temperature increases at a rate greater than 15 degrees F (9.4 degrees C) per